Blower type adsorption dryers, serie RDB

 
      Your benefits with Remeza RDB-Series Blower type adsorption dryers.
  • No loss of compressed air for regeneration or cooling
  • Pressure drop less than 0.1 bar at full capacity
  • Sophisticated PLC control and communication unit
  • Parallel drying phase for steady dewpoint performance
  • Low maintenance and long-life desiccant
   

Design specifications of RDB series adsorption dryers

  • Fully automatic continuous operation
  • Steel support frame with foundation holes
  • Pressure vessels according to various industrial design codes and regulations
  • "Heavy-duty" blower system
  • "Easy-access" heater system with single replaceable elements
  • Control box to IP54
  • Temperature and pressure indicators on both vessels
  • Compressor Start-Stop function linked into drying cycle
  • Dewpoint controlled cycle with indication and dewpoint setting
  • PLC (Siemens S-series) controls offering:
    • fully automatic cycle
    • alarm indication for all important dryer functions
    • memory of alarm hystory
    • fast-run cycle test
    • required service interval alarm
    • communication port to remote systems
  • Thermal insulation of all hot parts
  • Top to bottom flow direction avoiding fluidisation of adsorbent bed
  • HQ-Delsorb adsorbents for most economical use
  • Piping and vessels of carbon steel
  • Epoxy painting RAL 9001
  • All butterfly valves for lowest pressure drop

Available options according customer specifications, such as:

  • Installed filtration package
  • By-pass over complete dryer
  • Integrated refrigeration system (ask for HybriDryer® series documentation)
  • various makes PLC
  • Outdoor installation
  • Pressure dewpoint -70 ° C
  • Steam regeneration system
Design conditions Minimum Design Maximum
Operating pressure 5 bar (g) 7 bar (g) 10 bar (g)
Inlet air temperature +5°C +35°C +45°C
Ambient temprature +0°C +25°C +40°C

Model Capacity Dimensions (mm) Weight Connection el. Consumption
m3/h* Width ( A ) Depth ( B ) Height ( C ) (kg) (Flange) Fan kW Heater kW Average kW
RDB-22 710 2160 1590 2925 1400 DN 80 3,0 9,0 6,6
RDB-23 985 2230 1590 2925 1500 DN 80 3,0 13,2 9,0
RDB-24 1675 2230 1590 2925 2000 DN 80 3,0 21,3 15,0
RDB-25 2180 2420 1590 2925 2400 DN 80 3,0 25,5 19,3
RDB-26 2595 2730 1890 2985 2900 DN 100 5,5 32,4 23,0
RDB-27 3385 2830 1890 2985 3500 DN 100 5,5 40,8 29,8
RDB-28 4620 3640 2550 3270 4700 DN 150 7,5 53,7 40,6
RDB-29 5540 3840 2450 3270 5900 DN 150 7,5 66,3 49,1
RDB-30 6860 3940 2520 3270 6900 DN 150 11,0 80,1 60,4
RDB-31 8310 4040 2520 3270 7700 DN 150 11,0 96,9 74,8
RDB-32 9370 5380 2425 3035 10500 DN 200 11,0 114,0 84,1
RDB-33 10885 5380 2425 3085 11500 DN 200 11,0 132,0 98,1
RDB-34 11915 5580 2545 3085 12500 DN 200 15,0 144,0 107,3
RDB-35 13550 5625 2595 3085 13500 DN 200 15,0 162,0 121,4

  

Drying and regeneration cycle of RDB dryers:

  • Drying time is 6 hours minimum. The dewpoint controller will extend until complete saturation is reached.
  • Depressurisation time of saturated adsorber lasts 10 minutes.
  • Heating period is temperature controlled (TS1) and relates to the saturation degree of the desiccant.
  • Cooling with ambient air during 75 minutes.
  • Pressurisation time of regenerated adsorber lasts 10 minutes.
  • Stand-by time untill adsorption time of drying adsorber is completed.
  • Change-over period of parallel drying for 10 minutes.

Top to Bottom flow direction in all cycle phases offer following advantages:

  • No desiccant fluidisation at compressor start-up
  • The fan is not loaded with warm, humid and dusty regeneration air.
  • Pushed foreward "hot zone" in cooling phase optimizes regeneration effect..
  • Pre-loading by ambient moisture will not reach the outlet of the drying adsorber.
  • No compressed are is needed to support the cooling process.

F1 Multiplier for different inlet pressures in
Pressure bar (g) 5 6 7 8 9 10
Multiplier F1 0,69 0,85 1,00 1,12 1,25 1,37
F2 Multiplier for different inlet temperatures
Temperature °C +30 +35 +40
Multiplier F2 1,30 1,00 0,74
.